Beijing Hongrunda Sci-Tech Development Co., Ltd.
Main products:ventilator,anesthesia machine
Products
Contact Us
  • Contact Person : Ms. CHEN CATHY
  • Company Name : Beijing Hongrunda Sci-Tech Development Co., Ltd.
  • Tel : 86-010-68233393
  • Fax : 86-010-68233313
  • Address : Beijing,beijing,F1 of EAST WHITE BUILDING, No.38 of TAI PING ROAD, Haidian District, Beijing, China
  • Country/Region : China
  • Zip : 100039

Anesthesia machine CE EURO

Anesthesia machine CE EURO
Product Detailed
1.CE marked Anesthesia machine 2.3 gas&6 tube flowmeter 3.O2 concentration, breathing YOKE,PIN INDEX ETCO2

Anesthesia Machine

Main Frame

Inside 10.4" Colorful TFT High-Luminance LCD Display, and Keys Conditioning Means

Double-End Pressure-Flow Sensor, Such as Tidal Volume, Minute Volume, Respiratory Rate and Airway

Pressure, Pressure Waveform, Oxygen Concentration, Suffocation Can Be Real-Time Detection of Manual

Control and Automatic Control

Working Mode: For the Closed System, Semi-Closed System and Semi-Open System

Application: Adult and Infant

24-Hour Whole Parameter Trending Curve.

Alarms Parameters: Upper and Lower Airway Pressure Alarm; Upper and Lower Tidal Volume Alarm; Lack

of Oxygen Alarm; Apnea; Power Outages

Two High Precise Vaporizers, As customer requirements, Halothane,Sevoflurance, Enflurane and Isoflurane

Oxygen Flush: 35L/min~75L/min

Gas Supplies: O2:0.3MPa~0.5MPa; N2O: 0.3MPa~0.5MPa

Power: 220V±10%,50Hz±1%

OPTIONAL: ETCO2 function, YOKE, pin index

 

Anesthesia Ventilator

Two Bellows: Adult and Infant

Pneumatically Driven and Electrically Controlled, High-Luminance LCD Display, and Keys Conditioning

Means

Monitoring Parameters: Tidal Volume, the Respiratory Rate; I/E Ratio; the Peak Airway Pressure; Airway Pressure Waveform

Working Mode: Manual Control or Automatic Control

Respiratory Modes: IPPV,SIGH(Deep Breaths/Per Time After Breathing 60 Times),SIMV/F/2,,SIPPV, Manual, optional: PEEP(+0.5kPa~+2kPa)

Tidal Volume: 0, 20~1500ml

Respiratory Rate: 4~60bpm

I/E Ratio: 3; 1~1:4 Adjustable

Upper Airway Pressure: 2~6kPa

Lower Airway Pressure: 0.6-2kPa

Flow Meter

O2/N2O/Air Six-Tube Flow Meter

Linkage of O2 and N2O; Keep Oxygen Concentration Over 25%

Loop

Integrated Design, Orderliness Respiratory Loop

Vaporizer

Two High Precise Vaporizers, •Penlon or Drager

Scope of Concentration Regulation: 0.2~5%VOL

Automatic Compensation of Flow, Temperature and Pressure

Self-Lock and Interlock

Volume: 180ml

Anesthesia machine CE EURO



Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.